A specification and handover guide for detailing the junction between a cement-based exposed-aggregate pool finish and underwater acrylic or glass panels.

In short: Where a cement-based exposed-aggregate finish such as PebbleCrete meets an acrylic or glass pool window, detail the junction on construction drawings before site work starts. The specification should assign trade responsibilities, define a substrate rebate and include a flexible sealant recess confirmed by the window supplier and project designer. Because the finish is decorative, the project’s engineered window support, sealing and shell waterproofing arrangements must be completed, water-tested at the stage agreed by the pool designer before work is covered, and accepted before finishing.

Separating Waterproofing, Glazing Seals and the Decorative Finish

Whether a pool in Southeast Asia, the Middle East or another warm climate uses PebbleCrete Classic, PebbleCrete Supreme or PebbleCrete Glass, an exposed-aggregate finish is strictly a decorative layer, not a structural repair or waterproofing barrier.

Watertightness depends on the shell and the project’s engineered window support, sealing and waterproofing arrangements, designed by the named responsible specialists. The cementitious finish is decorative and does not stop leaks, while the perimeter sealant’s watertightness role must be defined by the window supplier and project designer. Shell waterproofing and window assemblies must be water-tested at the stage agreed by the pool designer before relevant work is covered, with written acceptance recorded before finishing.

Deciding Who Details and Coordinates the Junction

Improvising the window junction on site creates gaps between trades. Assign responsibilities during design development and show the coordinated detail on construction drawings:

Naming these roles in the specification clarifies who forms, inspects and accepts the opening and prepared base before finishing.

Showing a Defined Edge and Flexible Sealant Joint on Drawings

A concrete shell with a cement-based finish and an acrylic or glass panel behave differently under water load, thermal shifts and settlement. Specify the termination profile in the approved junction detail so the substrate rebate accommodates the specified finish build-up rather than tapering the edge or butting rigidly against the panel:

Specifying Visual Alignment, Physical Samples and Mock-Ups

Because water depth and lighting change how a finish reads against clear glazing, rely on physical references rather than screen images. When specifying PebbleCrete Classic, PebbleCrete Supreme or PebbleCrete Glass beside a window, record the material family, exact colour and sample reference together, review a current wet sample with the proposed sealant colour, and require an on-site mock-up of the approved termination and sealant detail.

Protecting Acrylic and Glass Panels During Pool Works

Site preparation and finishing work adjacent to glazing carry a risk of scratching, dust and chemical marking. Specify protection against scratching, impact and chemical contamination agreed with the window supplier:

Inspection and Acceptance at Handover

Review the junction at substrate acceptance, upon completion of the finish and sealant, and during pool start-up. The sealant joint between the finish and the panel can only be formed after the finish is complete, while the finish must be filled promptly once the installer releases the pool. Agree in advance with the window supplier and the applicator which sealant is used, how long it must cure before immersion and where it sits in the start-up programme. Confirm whether the window’s primary watertight seal depends on this joint; where it does, its cure time governs the filling date, and that must be written into the programme before finishing starts. At handover, inspect against the drawings, wet sample and mock-up:

Ongoing Care and Inspection of the Sealant Joint

A cement-based decorative finish depends on substrate preparation, application quality, water chemistry and routine maintenance, whereas the perimeter sealant joint is a serviceable component that ages differently. Handover documentation should establish:

Frequently asked questions

How should the junction between an exposed-aggregate pool finish and an acrylic or glass window be detailed?

Detail it on the construction drawings before site work: a defined substrate rebate or termination edge, a flexible sealant recess confirmed by the window supplier and the project designer, named responsibilities for each trade, panel protection during works, and a wet physical sample and on-site mock-up of the termination. The shell waterproofing and the window's engineered sealing are separate scopes, completed, water-tested and accepted before the decorative finish is applied.

Does an exposed-aggregate finish waterproof the junction around an underwater window?

No. A cement-based exposed-aggregate finish such as PebbleCrete is a decorative layer, not a waterproofing barrier. The perimeter sealant’s watertightness role must be defined by the window supplier and project designer, while shell waterproofing and engineered window sealing arrangements are separate scopes that must be completed, water-tested at the stage agreed by the pool designer before work is covered, and accepted before finishing.

Why is a flexible sealant joint required between the pool finish and the acrylic or glass panel?

Concrete shells, cementitious finishes and acrylic or glass panels move differently under water load and temperature changes. A defined rebate with a flexible sealant joint confirmed by the project designer and window supplier helps accommodate specified differential movement, limiting stress transfer to the panel and reducing the risk of the finish edge spalling.

How should the project team judge the completed window junction at handover?

Assess the junction against the coordinated drawings, approved wet PebbleCrete sample and mock-up. Verify a straight termination edge, appearance within agreed natural and hand-applied variation, a continuous and evenly finished sealant profile with no visible voids or detachment (plus any required verification records), and an unmarked panel once protection is removed.

Photographs and screen colours are illustrations. Confirm colour and texture with a current physical sample viewed wet and an approved on-site mock-up.

This article provides general technical guidance, not a design, installation or safety instruction for a specific pool. Every project depends on its structure, substrate, waterproofing, water conditions and local regulations. Refer to the current PebbleCrete technical documents: the Technical Data Sheet and the Installation Overview are available online, and the Safety Data Sheet and the full Method Statement are issued on request. Confirm structural, waterproofing, electrical and installation decisions with qualified professionals. PebbleCrete supplies the material only; unless agreed otherwise in writing, substrate preparation and application are carried out by the owner’s applicator, who is responsible for that work. Nothing in this article limits your statutory rights.